Wago - 750-407/040-000

$174.10
Wago - 750-407/040-000 is available to buy in increments of 1
Overview
2-channel digital input; 220 VDC; 3 ms; Extreme; dark gray
  • Environmental requirements - Operating altitude:without temperature derating: 0 ... 2000 m; with temperature derating: 2000 ... 5000 m (0.5 K/100 m); 5000 m (max.)
  • Technical data - Indicators:LED (A, E) green: Status DI 1, DI 2
  • Technical data - Number of outgoing power jumper contacts:3
  • Technical data - Number of incoming power jumper contacts:3
  • Technical data - Voltage range for signal (0):-3 ... +100 VDC
  • Technical data - Voltage range for signal (1):160 ... 286 VDC
  • Technical data - Input data width (internal) max.:2bits
  • Technical data - Input filter (digital):
    • 3
    • 3ms
  • Technical data - Supply voltage (system):5 VDC; via data contacts
  • Technical data - Supply voltage (field):220 VDC (-20 ... +25 %); via power jumper contacts (power supply via blade contact; transmission (supply voltage field side only) via spring contact)
  • Technical data - Current carrying capacity (power jumper contacts):10A
  • Material data - Color:dark gray
  • Technical data - Total number of channels (module):2
  • Technical data - Rated surge voltage:5.0 kV (EN 60870-2-1 / Class VW3); 4.0 kV (UL 508); 4.0 kV (EN 60664-1 / to 4,000 m ASL); 2.5 kV (EN 60664-1 / > 4,000 m to 5,000 m ASL)
  • Technical data - Dielectric strength:2.5°kV (AC) / 3.5°kV (DC); per EN°60870-2-1
  • Connection data - Connection type 1:Input
  • Connection data - Solid conductor:0.25 ... 2.5 mm2 / 24 ... 14 AWG
  • Connection data - Fine-stranded conductor:0.25 ... 2.5 mm2 / 24 ... 14 AWG
  • Mechanical Data - Mounting type:DIN-35 rail
  • Environmental requirements - Mounting position:horizontal (standing/lying); vertical
  • Technical data - Sensor connection:2 x (2-wire, 3-wire, 4-wire)
  • Technical data - Input characteristic:high-side switching
  • Technical data - Signal type:
    • Digital
    • Voltage
  • Technical data - Signal type (voltage):220 VDC
  • Physical data - Width:12 mm / 0.472 inches
  • Material data - Housing material:Polycarbonate; polyamide 6.6
  • Environmental requirements - Ambient temperature (operation):-40 ... +70 °C
  • Technical data - Derating:Current via power jumper contacts (max.): 10 mA (surrounding air (operating) temperature < 60°°C); 8°A (surrounding air (operating) temperature: 60 ... 70°°C)
  • Environmental requirements - Ambient temperature (storage):-40 ... +85 °C
  • Environmental requirements - Relative humidity (without condensation):0.95
  • Environmental requirements - Permissible H2S contaminant concentration at a relative humidity 75 %:10ppm
  • Environmental requirements - Permissible SO2 contaminant concentration at a relative humidity 75 %:25ppm
  • Environmental requirements - Relative humidity (with condensation):Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
  • Environmental requirements - Shock resistance:per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
  • Environmental requirements - Vibration resistance:per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
  • Technical data - Current consumption (5 V system supply):5mA
  • Technical data - Input current per channel for signal (1) typ.:1.2mA
  • Commercial data - GTIN:4050820000000
  • Commercial data - ETIM 8.0:EC001599
  • Commercial data - ETIM 7.0:EC001599
  • Commercial data - eClass 10.0:27-24-26-04
  • Commercial data - eClass 9.0:27-24-26-04
  • Commercial data - Customs tariff number:85389099990
  • sku_code:750-407/040-000
  • Environmental Product Compliance - RoHS Compliance Status:Compliant,With Exemption
  • approvals_General approvals:
    • KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-DIM750
    • UL - UL International Netherlands B.V. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.1
  • approvals_Approvals for marine applications:
    • ABS - American Bureau of Shipping - certificate 22-2208829-PDA
    • DNV - DNV GL SE - certificate TAA00000Y7
    • LR - Lloyds Register - certificate LR22276776TA
    • PRS - Polski Rejestr Statkow - certificate TE/1099/880590/23
  • Environmental Product Compliance - RoHS Exemption:
    • 7(a)
    • 7(c)-I
  • approvals_Approvals for hazardous areas:
    • ATEX - TUEV Nord Cert GmbH - EN 60079-0 - certificate TUEV 17 ATEX 193969X (II 3 G Ex ec IIC T4 Gc)
    • CCC - CNEX - CNCA-C23-01 - certificate 2020312310000214 (Ex ec IIC T4 Gc)
    • EAC - Brjansker Zertifizierungsstelle - TP TC 012/2011 - certificate EAC RU C-DE.AM02.B.00163/19 (2Ex e IIC T4 Gc X)
    • IECEx - TUEV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 16.0046X (Ex ec IIC T4 Gc)
    • UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX005X_ec
    • UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726 Sec.1
  • Environmental requirements - Exposure to pollutants:Per IEC 60068-2-42 and IEC 60068-2-43
  • Material data - Conformity marking:CE
  • Technical data - Overvoltage category:Nominal voltage 220 V: IV (EN 60664-1 / up to 5,000 m above sea level)
  • Commercial data - Country of origin:DE
  • Environmental requirements - Pollution degree:2 per EN 60664-1
  • ACCESSORIES_Markingaccessories:
    • 2009-145
    • 2009-145/000-002
    • 2009-145/000-005
    • 2009-145/000-006
    • 2009-145/000-007
    • 2009-145/000-012
    • 2009-145/000-023
    • 2009-145/000-024
    • 248-501
    • 248-501/000-002
    • 248-501/000-005
    • 248-501/000-006
    • 248-501/000-007
    • 248-501/000-012
    • 248-501/000-017
    • 248-501/000-023
    • 248-501/000-024
    • 750-103
    • 750-107
  • ACCESSORIES_Carrierrail:
    • 210-112
    • 210-113
    • 210-114
    • 210-115
    • 210-118
    • 210-196
    • 210-197
    • 210-198
    • 210-504
    • 210-505
    • 210-506
    • 210-508
  • ACCESSORIES_ShieldConnection:
    • 790-108
    • 790-116
    • 790-124
    • 790-140
    • 790-208
    • 790-216
    • 790-220
  • ACCESSORIES_SystemBox:
    • 850-814/002-000
    • 850-815/002-000
    • 850-816/002-000
    • 850-817/002-000
    • 850-825
    • 850-826
    • 850-826/002-000
    • 850-827
    • 850-827/002-000
    • 850-828
    • 850-828/002-000
    • 850-834
    • 850-835
    • 850-836
  • ACCESSORIES_Supplymodule:750-612/040-000
  • manufacturer_description:2-channel digital input; 220 VDC; 3 ms; Extreme
  • picture_filename_1:1024-020000180000122d000100b6-DE.jpg
  • picture_zoom_filename_1:2000-020000180000122d000100b6-DE.jpg
  • Material data - Weight:47g
  • Material data - Fire load:1.045MJ
  • picture_filename_2:1024-020000180000e2c3000100b6-EN.jpg
  • picture_zoom_filename_2:2000-020000180000e2c3000100b6-EN.jpg
  • Physical data - Height:100 mm / 3.937 inches
  • manufacturer_detailed_description:

    This digital input module receives control signals from field devices (e.g., sensors).

    The module is a 4-wire device allowing direct connection of sensors with functional ground contact.

    Each input module has a 3.0 ms noise-rejection filter.

    Field and system levels are electrically isolated.

    When using the functional ground CAGE CLAMP(R) connection, the field power must be reapplied after every seven digital input modules (750-407/040-000)!

    The device is ideal for operation in extreme environments thanks to:

    • An extended temperature range
    • Greater immunity to impulse voltages and electromagnetic interference
    • Higher vibration and shock resistance
  • Physical data - Depth:67.8 mm / 2.669 inches
  • Commercial data - Product Group:15 (I/O System)
  • picture_filename_3:1024-020000180000f668000100b6-EN.jpg
  • picture_zoom_filename_3:2000-020000180000f668000100b6-EN.jpg
  • picture_filename_4:1024-02000026000331ee000100b6-DE.jpg
  • picture_zoom_filename_4:2000-02000026000331ee000100b6-DE.jpg
  • Physical data - Depth from upper-edge of DIN-rail:60.6 mm / 2.386 inches
  • Environmental requirements - Protection type:IP20
  • Environmental requirements - EMC emission of interference:per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
  • Environmental requirements - EMC immunity to interference:per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;
    EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
  • Technical data - Number of digital inputs:2
  • Primary brand: Wago
  • Functions: Standard DC digital input slice module
  • Design: extended temperature range
  • Supply voltage (DC):
    • 5Vdc (supplied by system)
    • 176-275Vdc adjustable suppl. to field sensing devices
  • Connection type: Push-in spring CAGE CLAMP connections
  • Mounting mode: DIN-35 rail
  • Digital inputs:
    • 2 x digital inputs (220Vdc transistor; high-side switching; 2-wire / 3-wire / 4-wire; 3ms filter)
    • Digital inputs voltage ranges -3...+100Vdc (OFF) / 160-286Vdc (ON)
  • Dimensions: H100mm x W12mm x D67.8mm
  • Net Width (mm): 12mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: -40°C...+70°C
  • Ambient air temperature for storage: -40°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance:
    • Vibration resistance according to EN 60068-2-6 -- 5g
    • Shock resistance according to EN 60068-2-27 --15g (11ms / half-sine / 1000 shocks)
    • Shock resistance according to EN 60068-2-27 --25g (6ms / 1000 shocks)
  • Current consumption: 5mA (5Vdc; system supply)
  • GTIN code: 4050820000000
  • ETIM code: EC001599
  • eClass code: 27-24-26-04
  • Customs Tariff Number: 85389099990
  • Order code / Manufacturer SKU: 750-407/040-000
  • Manufacturer product status: Commercialized
  • Equivalent to: 750407000000
  • EAN code: 4050820000000
  • Compliant with standard(s):
    • EMC immunity to interference
    • - EN 61000-6-1
    • - EN 61000-6-2
    • - EN 61131-2
    • - marine applications
    • - EN 50121-3-2
    • - EN 50121-4
    • - EN 50121-5
    • - EN 60255-26
    • - EN 60870-2-1
    • - EN 61850-3
    • - IEC 61000-6-5
    • - IEEE 1613
    • - VDEW (1994)
    • EMC emission of interference
    • - EN 61000-6-3
    • - EN 61000-6-4
    • - EN 61131-2
    • - EN 60255-26
    • - marine applications
    • - EN 60870-2-1
    • - EN 61850-3
    • - EN 50121-3-2
    • - EN 50121-4
    • - EN 50121-5
    • General approvals
    • - KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-DIM750
    • - UL - UL International Netherlands B.V. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.1
    • Approvals for marine applications
    • - ABS - American Bureau of Shipping - certificate 22-2208829-PDA
    • - DNV - DNV GL SE - certificate TAA00000Y7
    • - LR - Lloyds Register - certificate LR22276776TA
    • - PRS - Polski Rejestr Statkow - certificate TE/1099/880590/23
    • Approvals for hazardous areas
    • - ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV 17 ATEX 193969X (II 3 G Ex ec IIC T4 Gc)
    • - CCC - CNEX - CNCA-C23-01 - certificate 2020312310000214 (Ex ec IIC T4 Gc)
    • - EAC - Brjansker Zertifizierungsstelle - TP TC 012/2011 - certificate EAC RU C-DE.AM02.B.00163/19 (2Ex e IIC T4 Gc X)
    • - IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 16.0046X (Ex ec IIC T4 Gc)
    • - UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX005X_ec
    • - UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726 Sec.1
    • RoHS compliant with exemption (7(a) / 7(c)-I)
  • Location of origin: Germany
  • Degree of pollution: 2
  • Cross-sells with:
    • 2009-145
    • 2009-145/000-002
    • 2009-145/000-005
    • 2009-145/000-006
    • 2009-145/000-007
    • 2009-145/000-012
    • 2009-145/000-023
    • 2009-145/000-024
    • 210-112
    • 210-113
    • 210-114
    • 210-115
    • 210-196
    • 210-197
    • 210-198
    • 210-504
    • 210-505
    • 210-506
    • 210-508
    • 248-501
    • 248-501/000-002
    • 248-501/000-005
    • 248-501/000-006
    • 248-501/000-007
    • 248-501/000-012
    • 248-501/000-017
    • 248-501/000-023
    • 248-501/000-024
    • 750-103
    • 750-107
    • 750-612/040-000
    • 790-108
    • 790-116
    • 790-124
    • 790-140
    • 790-208
    • 790-216
    • 790-220
    • 850-814/002-000
    • 850-815/002-000
    • 850-816/002-000
    • 850-817/002-000
    • 850-825
    • 850-826
    • 850-826/002-000
    • 850-827
    • 850-827/002-000
    • 850-828
    • 850-828/002-000
    • 850-834
    • 850-835
    • 850-836
  • Level 1 category: Automation components
  • Level 2 category: Programmable Logic Controllers & components
  • Level 3 category: I-O Units
  • Product title: Standard DC digital input slice module - Wago (XTR)
More Information
Main function I/O unit
Product series / family name 750 series
Sub-range name XTR
Connection type (electrical) Terminals (Spring)
Mounting mode DIN rail
Digital inputs quantity 2
Digital inputs type DC
Digital outputs quantity no digital outputs
Analog inputs quantity no analog inputs
Analog outputs quantity no analog outputs
Degree of protection IP20
Type - Installation in cabinet
Type - Option extended temperature range, special switching version (high-side switching)
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Copyright © 2023 US Automation Controls LLC, All Rights Reserved.