Pizzato CS AM-01ME01 Standstill monitor safety module, 2NO+1NC, category 3
Pizzato CS AM-01ME01
General data
SIL level (SIL CL) up to: SIL CL 2 acc. to EN 62061
Performance Level (PL) up to: PL d acc. to EN ISO 13849-1
Safety category up to: cat. 3 acc. to EN ISO 13849-1
Ambient temperature: -25°C...+55°C
Mechanical endurance: >10 million operating cycles
Electrical endurance: >100,000 operating cycles
Pollution degree: external 3, internal 2
Rated impulse withstand voltage (Uimp): 4 kV
Rated insulation voltage (Ui): 250 V
Overvoltage category: II
Main features
•For safety applications up to SIL CL 2/PL d
•Select from 10 different residual voltages on motor standstill.
•Galvanic separation between control circuit and measurement circuit.
•45 mm housing
•2 NO safety contacts
1 NC auxiliary contact
•2 semiconductor outputs:
- - 1 signalling output for failure state
- - 1 signalling output for switching state of
safety relays
•Possibility to connect single-phase or three- phase motors to measuring circuits.
•Supply voltages: 24 ... 230 Vac/dc
Mfg Part Number | 8824 |
---|---|