Wago - 750-660/000-001
- Technical data - Configuration options:PROFIsafe address adjustable via DIP switch or engineering software
- Environmental requirements - Operating altitude:0 ... 2000 m / 0 ... 6562 ft
- Technical data - Indicators:LED (A-H) green: Status I1 ... I8; LED (I-K) red: internal, external; LED (L) yellow: error operator
- Technical data - Number of outgoing power jumper contacts:2
- Technical data - Number of incoming power jumper contacts:2
- Technical data - Supply voltage (system):5 VDC; via data contacts
- Technical data - Supply voltage (field):24 VDC (-15 ... +20 %); via power jumper contacts (power supply via blade contact; transmission (supply voltage field side only) via spring contact)
- Technical data - Current carrying capacity (power jumper contacts):10A
- Material data - Color:yellow
- Technical data - Total number of channels (module):8
- Technical data - Isolation:500 V system/field
- Connection data - Connection type 1:Inputs/Outputs
- Connection data - Solid conductor:0.08 ... 2.5 mm2 / 28 ... 14 AWG
- Connection data - Fine-stranded conductor:0.08 ... 2.5 mm2 / 28 ... 14 AWG
- Mechanical Data - Mounting type:DIN-35 rail
- Environmental requirements - Mounting position:horizontal (standing/lying); vertical
- Technical data - Sensor connection:8 x (Fail-safe input with test pulse)
- Technical data - Input characteristic:clock sensitive
- Technical data - Signal type:
- Digital
- Voltage
- Technical data - Signal type (voltage):24 VDC
- Functional Safety - Response times (min. ... max.):ton (L->H) = 13 ms ... 71 ms; toff (H->L) = 13 ms ... 26 ms; plus 2 x local bus runtime; plus 2 x fieldbus runtime; plus PLC runtime
- Physical data - Width:24 mm / 0.945 inches
- Material data - Housing material:Polycarbonate; polyamide 6.6
- Environmental requirements - Ambient temperature (operation):0 ... +55 °C
- Environmental requirements - Ambient temperature (storage):-25 ... +85 °C
- Environmental requirements - Relative humidity (without condensation):0.95
- Environmental requirements - Permissible H2S contaminant concentration at a relative humidity
75 %:10ppm - Environmental requirements - Permissible SO2 contaminant concentration at a relative humidity
75 %:25ppm - Environmental requirements - Shock resistance:15g per IEC 60068-2-27
- Environmental requirements - Vibration resistance:per IEC 60068-2-6
- Technical data - Current consumption (5 V system supply):40mA
- Technical data - Input current per channel for signal (1) typ.:2.2mA
- Commercial data - GTIN:4045450000000
- Commercial data - ETIM 8.0:EC001599
- Commercial data - ETIM 7.0:EC001599
- Commercial data - eClass 10.0:27-24-26-04
- Commercial data - eClass 9.0:27-24-26-04
- Commercial data - Customs tariff number:85389099990
- sku_code:750-660/000-001
- Environmental Product Compliance - RoHS Compliance Status:Compliant,With Exemption
- approvals_General approvals:
- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-DIM750
- UL - UL International Netherlands B.V. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.1
- approvals_Declarations of conformity and manufacturer's declarations:
- EU-Declaration of Conformity - WAGO GmbH & Co. KG - certificate -
- UK-Declaration of Conformity - WAGO GmbH & Co. KG - certificate -
- Environmental Product Compliance - RoHS Exemption:
- 6(c)
- 7(a)
- 7(c)-I
- 7(c)-II
- approvals_Approvals for hazardous areas:
- ATEX - TUEV Nord Cert GmbH - EN 60079-0 - certificate TUEV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)
- CCCEx - CQST/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)
- IECEx - TUEV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)
- INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X
- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec
- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726 Sec.1
- Environmental requirements - Exposure to pollutants:Per IEC 60068-2-42 and IEC 60068-2-43
- Material data - Conformity marking:CE
- Functional Safety - Safety standards:IEC 61508-1 ... -7; EN 954-1 Cat. 4
- Commercial data - Country of origin:DE
- Environmental requirements - Pollution degree:2 per IEC 61131-2
- ACCESSORIES_Markingaccessories:
- 2009-145
- 2009-145/000-002
- 2009-145/000-005
- 2009-145/000-006
- 2009-145/000-007
- 2009-145/000-012
- 2009-145/000-023
- 2009-145/000-024
- 248-501
- 248-501/000-002
- 248-501/000-005
- 248-501/000-006
- 248-501/000-007
- 248-501/000-012
- 248-501/000-017
- 248-501/000-023
- 248-501/000-024
- 750-103
- 750-107
- ACCESSORIES_Carrierrail:
- 210-112
- 210-113
- 210-114
- 210-115
- 210-118
- 210-196
- 210-197
- 210-198
- 210-504
- 210-505
- 210-506
- 210-508
- ACCESSORIES_ShieldConnection:
- 790-108
- 790-116
- 790-124
- 790-140
- 790-208
- 790-216
- 790-220
- ACCESSORIES_SystemBox:
- 850-814/002-000
- 850-815/002-000
- 850-816/002-000
- 850-817/002-000
- 850-825
- 850-826
- 850-826/002-000
- 850-827
- 850-827/002-000
- 850-828
- 850-828/002-000
- 850-834
- 850-835
- 850-836
- ACCESSORIES_Supplymodule:
- 750-601
- 750-602
- 750-610
- 750-612
- manufacturer_description:Fail-safe 8-channel digital input; 24 VDC; PROFIsafe
- picture_filename_1:1024-0200000e0003164f000100b6-DE.jpg
- picture_zoom_filename_1:2000-0200000e0003164f000100b6-DE.jpg
- Material data - Weight:102g
- Material data - Fire load:3.418MJ
- picture_filename_2:1024-020000000003afbe000100b6-EN.jpg
- picture_zoom_filename_2:2000-020000000003afbe000100b6-EN.jpg
- Physical data - Height:100 mm / 3.937 inches
- manufacturer_detailed_description:
This PROFIsafe Input Module (750-660/000-001) connects to emergency stop buttons, limit sensors, safety interlock switches and other safety sensors with contacts.
The module features eight clock-sensitive inputs (I1 ... I8) that are fed via eight differently clocked outputs (T1 ... T8).
Clock outputs are short-circuit-protected. Inputs are continually monitored for cross circuits and power supply from separate sources.
The associated LED for each of the eight input channels indicates the signal state. Two red LEDs also indicate internal or external errors.
The PROFIsafe address can be set using the DIP switch located on the side of the module.
Field and system levels are electrically isolated.
Individual modules can be arranged in any combination when configuring the fieldbus node. An arrangement in groups is not necessary.
Reference the product manual for further information!
When implementing new installations, please consider WAGO's 750-662/000-004 PROFIsafe 8-Channel Digital Input Safety Module.
The module can only be used under PROFIBUS in combination with the 750-333 Fieldbus Coupler. Please note that this module only supports PROFIsafe V1.3.
- Physical data - Depth:67.8 mm / 2.669 inches
- Commercial data - Product Group:15 (I/O System)
- picture_filename_3:1024-020000000003b9e6000100b6-DE.jpg
- picture_zoom_filename_3:2000-020000000003b9e6000100b6-DE.jpg
- picture_filename_4:1024-02000026000396c5000100b6-DE.jpg
- picture_zoom_filename_4:2000-02000026000396c5000100b6-DE.jpg
- Physical data - Depth from upper-edge of DIN-rail:60.6 mm / 2.386 inches
- Environmental requirements - Protection type:IP20
- Environmental requirements - EMC emission of interference:per EN 61000-6-4
- Environmental requirements - EMC immunity to interference:per EN 61000-6-2
- Technical data - Number of digital inputs:8
- Primary brand: Wago
- Functions: Fail-safe / safety DC digital input slice module
- Supply voltage (DC):
- 5Vdc (supplied by system)
- 20.4-28.8Vdc adjustable suppl. to field sensing devices
- Programming languages:
- Configuration options
- - PROFIsafe address adjustable via DIP switch or engineering software
- Connection type: Push-in spring CAGE CLAMP connections
- Mounting mode: DIN-35 rail
- Digital inputs: 8 x digital inputs (fail-safe inputs with test pulse; clock sensitive; 24Vdc)
- Dimensions: H100mm x W24mm x D67.8mm
- Net Width (mm): 24mm
- Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
- Ambient air temperature for operation: 0°C...+55°C
- Ambient air temperature for storage: -25°C...+85°C
- Humidity: 95% relative humidity (RH; non-condensing)
- Mechanical resistance: Shock resistance according to EN 60068-2-27 --15g
- Current consumption: 40mA (5Vdc; system supply)
- GTIN code: 4045450000000
- ETIM code: EC001599
- eClass code: 27-24-26-04
- Customs Tariff Number: 85389099990
- Order code / Manufacturer SKU: 750-660/000-001
- Manufacturer product status: Commercialized
- Equivalent to: 750660000000
- EAN code: 4045450000000
- Compliant with standard(s):
- IEC61508-1
- IEC61508-2
- IEC61508-3
- IEC61508-4
- IEC61508-5
- IEC61508-6
- IEC61508-7
- EN 954-1 Cat.4
- EMC immunity to interference
- - EN 61000-6-2
- EMC emission of interference
- - EN 61000-6-4
- General approvals
- - KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-DIM750
- - UL - UL International Netherlands B.V. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.1
- Declarations of conformity and manufacturer's declarations
- - EU-Declaration of Conformity - WAGO GmbH & Co. KG
- - UK-Declaration of Conformity - WAGO GmbH & Co. KG
- Approvals for hazardous areas
- - ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV14ATEX148929X (II 3 G Ex ec IIC T4 Gc)
- - CCCEx - CQST/CNEx - CNCA-C23-01 - certificate 2020312310000213 (Ex ec IIC T4 Gc)
- - IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 14.0035 X (Ex ec IIC T4 Gc)
- - INMETRO - TUV Rheinland do Brasil Ltda. - IEC 60079-0 - certificate TUV 12.1297 X
- - UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX003X_ec
- - UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726 Sec.1
- RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
- Class: Safety Cat2/SIL2 or Cat4/SIL3
- Location of origin: Germany
- Degree of pollution: 2
- Cross-sells with:
- 2009-145
- 2009-145/000-002
- 2009-145/000-005
- 2009-145/000-006
- 2009-145/000-007
- 2009-145/000-012
- 2009-145/000-023
- 2009-145/000-024
- 210-112
- 210-113
- 210-114
- 210-115
- 210-196
- 210-197
- 210-198
- 210-504
- 210-505
- 210-506
- 210-508
- 248-501
- 248-501/000-002
- 248-501/000-005
- 248-501/000-006
- 248-501/000-007
- 248-501/000-012
- 248-501/000-017
- 248-501/000-023
- 248-501/000-024
- 750-103
- 750-107
- 750-601
- 750-602
- 750-610
- 750-612
- 790-108
- 790-116
- 790-124
- 790-140
- 790-208
- 790-216
- 790-220
- 850-814/002-000
- 850-815/002-000
- 850-816/002-000
- 850-817/002-000
- 850-825
- 850-826
- 850-826/002-000
- 850-827
- 850-827/002-000
- 850-828
- 850-828/002-000
- 850-834
- 850-835
- 850-836
- Level 1 category: Safety components
- Level 2 category: Safety I-O Units
- Product title: Fail-safe / safety DC digital input slice module - Wago
Main function | Safety I/O unit |
---|---|
Product series / family name | 750 series |
Connection type (electrical) | Terminals (Spring) |
Communication protocol | PROFIsafe |
Mounting mode | DIN rail |
Digital inputs quantity | 8 |
Digital inputs type | DC |
Digital outputs quantity | no digital outputs |
Analog inputs quantity | no analog inputs |
Analog outputs quantity | no analog outputs |
Degree of protection | IP20 |
Type - Installation | in cabinet |
Type - Option | Standard (No options) |