Wago - 750-481/003-000

$0.00
  • Technical data - Configuration options:
    • WAGO-I/O-CHECK
    • CODESYS Library
    • e!COCKPIT
  • Environmental requirements - Operating altitude:0 ... 2000 m / 0 ... 6562 ft
  • Technical data - Indicators:LED (A, E) green: Function AI 1, AI 2; LED (B, F) red: Error AI 1, AI 2
  • Technical data - Number of outgoing power jumper contacts:2
  • Technical data - Number of incoming power jumper contacts:2
  • Technical data - Data width:2 x 16-bit data; 2 x 8-bit control/status (optional)
  • Technical data - Intrinsic safety Ex i:Yes
  • Technical data - Supply voltage (system):5 VDC; via data contacts
  • Technical data - Supply voltage (field):24 VDC; (Ex i power supply: Uo = max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)
  • Technical data - Current carrying capacity (power jumper contacts):1A
  • Technical data - Total number of channels (module):2
  • Technical data - Isolation:300 VAC system/supply
  • Connection data - Connection type 1:Inputs/outputs
  • Mechanical data - Mounting type:DIN-35 rail
  • Environmental requirements - Mounting position:horizontal (standing/lying); vertical
  • Technical data - Signal type:
    • Resistance measurement
    • Potentiometer positions
  • Technical data - Sensor types:Pt100; Configurable: Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000; Potentiometer setting 0 ... 100 %: 1k2, 5k0
  • Technical data - Signal type (configurable):Yes
  • Technical data - Measurement error, deviation (max.) from the upper-range value:0.002
  • Technical data - Measurement error (reference temperature):25°C
  • Technical data - Temperature error (max.) of the upper-range value:0.01%/K
  • Material data - Housing material:Polycarbonate; polyamide 6.6
  • Environmental requirements - Relative humidity (without condensation):0.95
  • Environmental requirements - Permissible H2S contaminant concentration at a relative humidity 75 %:10ppm
  • Environmental requirements - Permissible SO2 contaminant concentration at a relative humidity 75 %:25ppm
  • Environmental requirements - Shock resistance:15g per IEC 60068-2-27
  • Environmental requirements - Vibration resistance:4g per IEC 60068-2-6
  • Technical data - Conversion time (typ.):325ms
  • Technical data - Conversion time:150 ... 500 ms (per channel)
  • Technical data - Current consumption (5 V system supply):25mA
  • Technical data - Current consumption, field supply (module with no external load):12mA
  • Technical data - Power consumption Pmax.:0.45 W
  • Commercial data - ETIM 8.0:
    • EC001596
  • Commercial data - ETIM 7.0:
    • EC001596
  • Commercial data - eClass 10.0:27-24-26-01
  • Commercial data - eClass 9.0:
    • 27-24-26-01
  • Technical data - Power loss Pl:0.45 W
  • sku_code:750-481/003-000
  • Commercial data - End of Sale:44561
  • Commercial data - End of Delivery:44621
  • Commercial data - End of Production:44196
  • Commercial data - End of Service and Repair:45291
  • Environmental Product Compliance - RoHS Compliance Status:Compliant,With Exemption
  • approvals_General approvals:
    • KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-AIM750
    • UL - UL International Netherlands B.V. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.1
  • approvals_Declarations of conformity and manufacturer's declarations:EU-Declaration of Conformity - WAGO GmbH & Co. KG - certificate -
  • approvals_Approvals for marine applications:
    • ABS - American Bureau of Shipping - certificate 22-2219060
    • BV - Bureau Veritas S.A. - certificate 30389/C0 BV
    • DNV - DNV GL SE - DNV-CG-0339 / Aug.2021 - certificate TAA0000194
    • KR - Korean Register of Shipping - certificate KR HMB05880-AC001
    • LR - Lloyds Register EMEA - certificate LR22180952TA
    • PRS - Polski Rejestr Statkow - certificate TE/1101/880590/23
    • RINA - RINA Germany GmbH - certificate ELE343521XG001
  • Environmental Product Compliance - RoHS Exemption:
    • 6(c)
    • 7(a)
    • 7(c)-I
    • 7(c)-II
  • approvals_Approvals for hazardous areas:
    • AEx - UL International Germany GmbH - UL 60079 - certificate E480271
    • ATEX - TUEV Nord Cert GmbH - EN 60079-0 - certificate TUEV_12_ATEX_106032X (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)
    • CCC - CNEX - CNCA-C23-01 - certificate 2020312310000211 (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)
    • INMETRO - TUV Rheinland do Brasil Ltda. - certificate TUV_14.1911_X
    • TUEV Nord - TUEV Nord Cert GmbH - IEC 60079 - certificate IECEx TUN 12.0039X (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)
    • UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726 Sec.1
  • Environmental requirements - Exposure to pollutants:per IEC 60068-2-42 and IEC 60068-2-43
  • Material data - Conformity marking:CE
  • Explosion protection - Ex standard:EN IEC 60079-0, -7, -11
  • Explosion protection - Marking:ATEX/IECEx: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I
  • Environmental requirements - Pollution degree:2 per IEC 61131-2
  • ACCESSORIES_Markingaccessories:
    • 2009-145
    • 2009-145/000-002
    • 2009-145/000-005
    • 2009-145/000-006
    • 2009-145/000-007
    • 2009-145/000-012
    • 2009-145/000-023
    • 2009-145/000-024
    • 248-501
    • 248-501/000-002
    • 248-501/000-005
    • 248-501/000-006
    • 248-501/000-007
    • 248-501/000-012
    • 248-501/000-017
    • 248-501/000-023
    • 248-501/000-024
    • 750-103
    • 750-107
  • ACCESSORIES_Carrierrail:
    • 210-112
    • 210-113
    • 210-114
    • 210-115
    • 210-118
    • 210-196
    • 210-197
    • 210-198
    • 210-504
    • 210-505
    • 210-506
    • 210-508
  • ACCESSORIES_ShieldConnection:
    • 790-108
    • 790-116
    • 790-124
    • 790-140
    • 790-208
    • 790-216
    • 790-220
  • ACCESSORIES_Supplymodule:
    • 750-606
    • 750-625/000-001
  • manufacturer_description:2-channel analog input; Resistance measurement; Intrinsically safe
  • picture_filename_1:1024-0200000f000194d2000100b6-DE.jpg
  • picture_zoom_filename_1:2000-0200000f000194d2000100b6-DE.jpg
  • Material data - Weight:92.7g
  • Material data - Fire load:2.299MJ
  • picture_filename_2:1024-020000000003ae92000100b6-EN.jpg
  • picture_zoom_filename_2:2000-020000000003ae92000100b6-EN.jpg
  • manufacturer_detailed_description:

    This analog input module directly connects to Pt and Ni resistance sensors or potentiometers located in hazardous areas of Zones 0 and 1.

    The WAGO I/O System 750 must be installed either in Zone 2 or in a non-hazardous area. The 24 V supply is derived from the module's power jumper contacts.

    The shield directly connects to the DIN-rail.

    Indicators:

    • Green LED (availability ON/OFF)
    • Red LED (short circuit, wire breakage, measurement range overflow/underflow)

    Field and system levels are electrically isolated.

  • Commercial data - Product Group:15 (I/O System)
  • picture_filename_3:1024-020000000003b8ba000100b6-EN.jpg
  • picture_zoom_filename_3:2000-020000000003b8ba000100b6-EN.jpg
  • picture_filename_4:1024-0200002600035585000100b6-DE.jpg
  • picture_zoom_filename_4:2000-0200002600035585000100b6-DE.jpg
  • Physical data - Depth from upper-edge of DIN-rail:60.6 mm / 2.386 inches
  • Environmental requirements - Protection type:IP20
  • Environmental requirements - EMC emission of interference:per EN 61000-6-3, marine applications
  • Environmental requirements - EMC immunity to interference:per EN 61000-6-2, marine applications
  • Technical data - Number of analog inputs:2
  • Technical data - Resolution (over entire range):0.1 °C, 0.1 Ω, 0.0049 %
  • Technical data - Temperature range:−200 ... +850 °C (Pt), −60 ... +250 °C (Ni), −80 ... +320 °C (Ni120)
  • Primary brand: Wago
  • Functions: Intrinsically-safe analog input slice module
  • Supply voltage (DC):
    • 5Vdc (supplied by system)
    • 24Vdc fixed suppl. to field sensing devices
  • Programming languages:
    • Configuration options
    • - WAGO-I/O-CHECK
    • - CODESYS Library
    • - e!COCKPIT
  • Connection type: Push-in spring CAGE CLAMP connections
  • Mounting mode: DIN-35 rail
  • Analog inputs: 2 x analog inputs (Configurable RTD Pt100 / Pt200 / Pt500 / Pt1000 / Ni100 / Ni120 / Ni1000 / Potentiometer 1.2kΩ / 5kΩ; 0.1°C resolution / 325ms conversion; 2-wire / 3-wire)
  • Measurement accuracy:
    • +-0.2% (measuring error)
    • +-0.01% (temperature error)
  • Dimensions: H100mm x W24mm x D67.8mm
  • Net Width (mm): 24mm
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Ambient air temperature for operation: 0°C...+55°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Mechanical resistance:
    • Vibration resistance according to EN 60068-2-6 -- 4g
    • Shock resistance according to EN 60068-2-27 --15g
  • Current consumption:
    • 25mA (5Vdc; system supply)
    • 12mA (field supply; no external load)
  • ETIM code: EC001596
  • eClass code: 27-24-26-01
  • Power dissipation/losses: 0.45W
  • Order code / Manufacturer SKU: 750-481/003-000
  • Manufacturer product status: Discontinued
  • Equivalent to: 750481000000
  • Product lifecycle information:
    • End of life announced on -- 2022 Jan 04
    • End of sales -- 2021 Dec 31
    • End of production -- 2022 Feb 01
    • End of delivery -- 2022 Mar 01
    • End of service and repair -- 2023 Dec 31
  • Compliant with standard(s):
    • EMC immunity to interference
    • - EN 61000-6-2
    • - marine applications
    • EMC emission of interference
    • - EN 61000-6-3
    • - marine applications
    • General approvals
    • - KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-AIM750
    • - UL - UL International Netherlands B.V. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.1
    • Declarations of conformity and manufacturer's declarations
    • - EU-Declaration of Conformity - WAGO GmbH & Co. KG
    • Approvals for marine applications
    • - ABS - American Bureau of Shipping - certificate 22-2219060
    • - BV - Bureau Veritas S.A. - certificate 30389/C0 BV
    • - DNV - DNV GL SE - DNV-CG-0339 / Aug.2021 - certificate TAA0000194
    • - KR - Korean Register of Shipping - certificate KR HMB05880-AC001
    • - LR - Lloyds Register EMEA - certificate LR22180952TA
    • - PRS - Polski Rejestr Statkow - certificate TE/1101/880590/23
    • - RINA - RINA Germany GmbH - certificate ELE343521XG001
    • Approvals for hazardous areas
    • - AEx - UL International Germany GmbH - UL 60079 - certificate E480271
    • - ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV_12_ATEX_106032X (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)
    • - CCC - CNEX - CNCA-C23-01 - certificate 2020312310000211 (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)
    • - INMETRO - TUV Rheinland do Brasil Ltda. - certificate TUV_14.1911_X
    • - TUV Nord - TUV Nord Cert GmbH - IEC 60079 - certificate IECEx TUN 12.0039X (Ex ec[iaGa] IIC T4 Gc / [Ex iaDa] IIIC / [Ex iaMa] I)
    • - UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726 Sec.1
    • RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
  • Degree of pollution: 2
  • Cross-sells with:
    • 2009-145
    • 2009-145/000-002
    • 2009-145/000-005
    • 2009-145/000-006
    • 2009-145/000-007
    • 2009-145/000-012
    • 2009-145/000-023
    • 2009-145/000-024
    • 210-112
    • 210-113
    • 210-114
    • 210-115
    • 210-196
    • 210-197
    • 210-198
    • 210-504
    • 210-505
    • 210-506
    • 210-508
    • 248-501
    • 248-501/000-002
    • 248-501/000-005
    • 248-501/000-006
    • 248-501/000-007
    • 248-501/000-012
    • 248-501/000-017
    • 248-501/000-023
    • 248-501/000-024
    • 750-103
    • 750-107
    • 750-606
    • 750-625/000-001
    • 790-108
    • 790-116
    • 790-124
    • 790-140
    • 790-208
    • 790-216
    • 790-220
  • Level 1 category: Automation components
  • Level 2 category: Programmable Logic Controllers & components
  • Level 3 category: I-O Units
  • Product title: Intrinsically-safe analog input slice module - Wago
More Information
Main function I/O unit
Product series / family name 750 series
Connection type (electrical) Terminals (Spring)
Mounting mode DIN rail
Digital inputs quantity no digital inputs
Digital outputs quantity no digital outputs
Analog inputs quantity 2
Analog inputs type RTD, RTD type Ni1000
Analog outputs quantity no analog outputs
Degree of protection IP20
Type - Installation in cabinet
Type - Option intrinsically-safe
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Copyright © 2023 US Automation Controls LLC, All Rights Reserved.