Wago - 750-338/040-000
- Technical data - Other CANopen features:
- NMT slave
- Minimum boot-up
- Variable PDO mapping
- Emergency message
- Life guarding
- Empty module configuration
- Environmental requirements - Operating altitude:without temperature derating: 0 ... 2000 m; with temperature derating: 2000 ... 5000 m (0.5 K/100 m); 5000 m (max.)
- Technical data - Number of outgoing power jumper contacts:2
- Technical data - Number of modules per node (max.):64
- Technical data - Number of modules without a bus extension (max.):64
- Technical data - Number of fieldbus nodes on master (max.):110
- Technical data - Supply voltage (system):24 VDC; via pluggable connector (CAGE CLAMP(R) connection); Derating must be observed!
- Technical data - Supply voltage (field):24 VDC; Power supply via pluggable connector (CAGE CLAMP(R) connection); Transmission via power jumper contacts; Derating must be observed!
- Technical data - Current carrying capacity (power jumper contacts):10A
- Technical data - Rated surge voltage:1 kV
- Connection data - Connection type 1:System/field supply
- Connection data - Connection technology: communication/fieldbus:CANopen: 1 x D-sub 9 plug
- Connection data - Solid conductor:0.25 ... 2.5 mm2 / 24 ... 14 AWG
- Connection data - Fine-stranded conductor:0.25 ... 2.5 mm2 / 24 ... 14 AWG
- Technical data - Power supply efficiency (typ.) at nominal load (24 V):0.9
- Mechanical Data - Mounting type:DIN-35 rail
- Environmental requirements - Mounting position:horizontal (standing/lying); vertical
- Technical data - Baud rate:10 kBd ... 1 MBd
- Physical data - Width:50.5 mm / 1.988 inches
- Material data - Housing material:Polycarbonate; polyamide 6.6
- Environmental requirements - Ambient temperature (operation):-40 ... +70 °C
- Technical data - Derating:Derating (supply voltage):
Ambient temperatures under laboratory conditions: (-25 ... +30°%);
for -40 ... +55°°C: 24°V (-25 ... +20°%);
for +55 ... +70°°C: 24°V (-25 ... +10°%);
Lower limit in all temperature ranges: -27.5°% (including 15°% residual ripple) - Environmental requirements - Ambient temperature (storage):-40 ... +85 °C
- Environmental requirements - Relative humidity (without condensation):0.95
- Environmental requirements - Permissible H2S contaminant concentration at a relative humidity
75 %:10ppm - Environmental requirements - Permissible SO2 contaminant concentration at a relative humidity
75 %:25ppm - Environmental requirements - Relative humidity (with condensation):Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
- Environmental requirements - Shock resistance:per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
- Environmental requirements - Vibration resistance:per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
- Technical data - Current consumption (5 V system supply):350mA
- Technical data - Input current (typ.) at nominal load (24 V):500mA
- Technical data - Total current (system supply):1,650mA
- Commercial data - GTIN:4050820000000
- Commercial data - ETIM 8.0:EC001603
- Commercial data - ETIM 7.0:EC001603
- Commercial data - eClass 10.0:27-24-26-07
- Commercial data - eClass 9.0:27-24-26-07
- Commercial data - Customs tariff number:85176200000
- sku_code:750-338/040-000
- Environmental Product Compliance - RoHS Compliance Status:Compliant,With Exemption
- approvals_General approvals:
- KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-FBC750
- UL - UL International Netherlands B.V. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.1
- approvals_Declarations of conformity and manufacturer's declarations:
- EU-Declaration of Conformity - WAGO GmbH & Co. KG - certificate -
- UK-Declaration of Conformity - WAGO GmbH & Co. KG - certificate -
- approvals_Approvals for marine applications:
- ABS - American Bureau of Shipping - certificate 22-2208829-PDA
- DNV - DNV GL SE - certificate TAA00000Y7
- LR - Lloyds Register - certificate LR22276776TA
- PRS - Polski Rejestr Statkow - certificate TE/1099/880590/23
- Environmental Product Compliance - RoHS Exemption:
- 6(c)
- 7(a)
- 7(c)-I
- 7(c)-II
- approvals_Approvals for hazardous areas:
- ATEX - TUEV Nord Cert GmbH - EN 60079-0 - certificate TUEV 17 ATEX 193969X (II 3 G Ex ec IIC T4 Gc)
- CCC - CNEX - CNCA-C23-01 - certificate 2020312310000214 (Ex ec IIC T4 Gc)
- EAC - Brjansker Zertifizierungsstelle - TP TC 012/2011 - certificate EAC RU C-DE.AM02.B.00163/19 (2Ex e IIC T4 Gc X)
- IECEx - TUEV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 16.0046X (Ex ec IIC T4 Gc)
- UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX005X_ec
- UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726 Sec.1
- Environmental requirements - Exposure to pollutants:Per IEC 60068-2-42 and IEC 60068-2-43
- Material data - Conformity marking:CE
- Technical data - Ratings per:IEC/EN 60664-1
- Commercial data - Country of origin:DE
- Environmental requirements - Pollution degree:2 per IEC 61131-2
- ACCESSORIES_Markingaccessories:
- 2009-145
- 2009-145/000-002
- 2009-145/000-005
- 2009-145/000-006
- 2009-145/000-007
- 2009-145/000-012
- 2009-145/000-023
- 2009-145/000-024
- 248-501
- 248-501/000-002
- 248-501/000-005
- 248-501/000-006
- 248-501/000-007
- 248-501/000-012
- 248-501/000-017
- 248-501/000-023
- 248-501/000-024
- 750-103
- 750-107
- ACCESSORIES_Carrierrail:
- 210-112
- 210-113
- 210-114
- 210-115
- 210-118
- 210-196
- 210-197
- 210-198
- 210-504
- 210-505
- 210-506
- 210-508
- ACCESSORIES_ShieldConnection:
- 790-108
- 790-116
- 790-124
- 790-140
- 790-208
- 790-216
- 790-220
- ACCESSORIES_SystemBox:
- 850-814/002-000
- 850-815/002-000
- 850-816/002-000
- 850-817/002-000
- 850-825
- 850-826
- 850-826/002-000
- 850-827
- 850-827/002-000
- 850-828
- 850-828/002-000
- 850-834
- 850-835
- 850-836
- ACCESSORIES_WiringAndConnectors:750-963
- ACCESSORIES_Communication:
- 750-923
- 750-923/000-001
- manufacturer_description:Fieldbus Coupler CANopen; D-Sub; Extreme
- picture_filename_1:1024-0200001700017ad0000100b6-DE.jpg
- picture_zoom_filename_1:2000-0200001700017ad0000100b6-DE.jpg
- Material data - Weight:176.5g
- Material data - Fire load:2.18MJ
- picture_filename_2:1024-020000180000e1a3000100b6-EN.jpg
- picture_zoom_filename_2:2000-020000180000e1a3000100b6-EN.jpg
- Physical data - Height:100 mm / 3.937 inches
- manufacturer_detailed_description:
This fieldbus coupler connects the WAGO I/O System as a slave to the CANopen fieldbus. Data is transmitted via PDOs and SDOs.
The fieldbus coupler detects all connected I/O modules and creates a local process image. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit.
The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the CANopen bus to a control system for further processing. The process output data is sent via the CANopen bus.
The data of the analog modules is stored in the PDOs according to the order in which the modules are connected to the coupler. The bits of the digital modules are sent byte by byte and also mapped in the PDOs. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.
All entries of the object directory can be mapped as required in the 32 Rx PDOs and 32 Tx PDOs. The complete input and output process image can be transmitted via SDOs.
Spacer modules can be set via software.
The device is ideal for operation in extreme environments thanks to:
- An extended temperature range
- Greater immunity to impulse voltages and electromagnetic interference
- Higher vibration and shock resistance
- Physical data - Depth:71.1 mm / 2.799 inches
- Commercial data - Product Group:15 (I/O System)
- picture_filename_3:1024-020000180000f548000100b6-EN.jpg
- picture_zoom_filename_3:2000-020000180000f548000100b6-EN.jpg
- Physical data - Depth from upper-edge of DIN-rail:63.9 mm / 2.516 inches
- Environmental requirements - Protection type:IP20
- Environmental requirements - EMC emission of interference:per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
- Environmental requirements - EMC immunity to interference:per EN 61000-6-1, -2, EN 61131-2, marine applications, EN 50121-3-2, -4, -5, EN 60255-26
- Technical data - Communication:CANopen
- Technical data - Input and output process image (fieldbus) max.:512 bytes/512 bytes
- Technical data - Transmission medium:Shielded Cu cable 3 x 0.25 mm2
- Technical data - Communication profile:DS-301 V4.1
- Primary brand: Wago
- Functions: Fieldbus coupler / head (remote I/O (RIO) controller unit)
- Design: extended temperature range
- Supply voltage (DC): 24Vdc via wiring (system) + 24Vdc via pwr. jumper (Field)
- Connection capacity:
- 64 x connections per node
- 110 x fieldbus nodes on master
- Connection type:
- 9-pin D-sub connector
- Push-in spring CAGE CLAMP (pwr. suppl. connections)
- 4-pin male connector (device configuration)
- Mounting mode: DIN-35 rail
- Speed: 10kbit/s-1Mbit/s
- Dimensions: H100mm x W50.5mm x D71.1mm
- Net Width (mm): 50.5mm
- Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
- Ambient air temperature for operation: -40°C...+70°C
- Ambient air temperature for storage: -40°C...+85°C
- Humidity: 95% relative humidity (RH; non-condensing)
- Mechanical resistance:
- Vibration resistance according to EN 60068-2-6 -- 5g
- Shock resistance according to EN 60068-2-27 --15g (11ms / half-sine / 1000 shocks)
- Shock resistance according to EN 60068-2-27 --25g (6ms / 1000 shocks)
- Current consumption:
- 500mA (24Vdc; at nominal load)
- 350mA (5Vdc; system supply)
- 1650mA (system supply)
- GTIN code: 4050820000000
- ETIM code: EC001603
- eClass code: 27-24-26-07
- Customs Tariff Number: 85176200000
- Order code / Manufacturer SKU: 750-338/040-000
- Manufacturer product status: Commercialized
- Equivalent to: 750338000000
- EAN code: 4050820000000
- Compliant with standard(s):
- EMC immunity to interference
- - EN 61000-6-1
- - EN 61000-6-2
- - EN 61131-2
- - marine applications
- - EN 50121-3-2
- - EN 50121-3-4
- - EN 50121-3-5
- - EN 60255-26
- EMC emission of interference
- - EN 61000-6-3
- - EN 61000-6-4
- - EN 61131-2
- - EN 60255-26
- - marine applications
- - EN 60870-2-1
- - EN 61850-3
- - EN 50121-3-2
- - EN 50121-4
- - EN 50121-5
- General approvals
- - KC - National Radio Research Agency - Article 58-2 / Clause 3 - certificate MSIP-REM-W43-FBC750
- - UL - UL International Netherlands B.V. (ORDINARY LOCATIONS) - UL 508 - certificate E175199 Sec.1
- Declarations of conformity and manufacturer's declarations
- - EU-Declaration of Conformity - WAGO GmbH & Co. KG
- - UK-Declaration of Conformity - WAGO GmbH & Co. KG
- Approvals for marine applications
- - ABS - American Bureau of Shipping - certificate 22-2208829-PDA
- - DNV - DNV GL SE - certificate TAA00000Y7
- - LR - Lloyds Register - certificate LR22276776TA
- - PRS - Polski Rejestr Statkow - certificate TE/1099/880590/23
- Approvals for hazardous areas
- - ATEX - TUV Nord Cert GmbH - EN 60079-0 - certificate TUV 17 ATEX 193969X (II 3 G Ex ec IIC T4 Gc)
- - CCC - CNEX - CNCA-C23-01 - certificate 2020312310000214 (Ex ec IIC T4 Gc)
- - EAC - Brjansker Zertifizierungsstelle - TP TC 012/2011 - certificate EAC RU C-DE.AM02.B.00163/19 (2Ex e IIC T4 Gc X)
- - IECEx - TUV Nord Cert GmbH - IEC 60079-0 - certificate IECEx TUN 16.0046X (Ex ec IIC T4 Gc)
- - UKEx - WAGO GmbH & Co. KG - EN 60079-0 - certificate UKCA_WAGO22UKEX005X_ec
- - UL - Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS) - UL 121201 - certificate E198726 Sec.1
- RoHS compliant with exemption (6(c) / 7(a) / 7(c)-I / 7(c)-II)
- Location of origin: Germany
- Degree of pollution: 2
- Cross-sells with:
- 2009-145
- 2009-145/000-002
- 2009-145/000-005
- 2009-145/000-006
- 2009-145/000-007
- 2009-145/000-012
- 2009-145/000-023
- 2009-145/000-024
- 210-112
- 210-113
- 210-114
- 210-115
- 210-196
- 210-197
- 210-198
- 210-504
- 210-505
- 210-506
- 210-508
- 248-501
- 248-501/000-002
- 248-501/000-005
- 248-501/000-006
- 248-501/000-007
- 248-501/000-012
- 248-501/000-017
- 248-501/000-023
- 248-501/000-024
- 750-103
- 750-107
- 750-923
- 750-923/000-001
- 750-963
- 790-108
- 790-116
- 790-124
- 790-140
- 790-208
- 790-216
- 790-220
- 850-814/002-000
- 850-815/002-000
- 850-816/002-000
- 850-817/002-000
- 850-825
- 850-826
- 850-826/002-000
- 850-827
- 850-827/002-000
- 850-828
- 850-828/002-000
- 850-834
- 850-835
- 850-836
- Level 1 category: Automation components
- Level 2 category: Programmable Logic Controllers & components
- Level 3 category: I-O Units
- Product title: Fieldbus coupler / head (remote I/O (RIO) controller unit) - Wago (XTR)
Main function | Remote I/O controller |
---|---|
Product series / family name | 750 series |
Sub-range name | XTR |
Supply voltage (DC) | 24Vdc |
Connection type (electrical) | D-Sub connector, Terminals (Spring) |
Communication protocol | CANopen |
Mounting mode | DIN rail |
Digital inputs quantity | no digital inputs |
Digital outputs quantity | no digital outputs |
Analog inputs quantity | no analog inputs |
Analog outputs quantity | no analog outputs |
Degree of protection | IP20 |
Type - Installation | in cabinet |
Type - Option | extended temperature range |