Wago - 787-783/000-040

$120.10
Wago - 787-783/000-040 is available to buy in increments of 1
Overview
RDM 2x DC 9-54V, 1 pcs.
  • Technical data - Input - Nominal mains frequency range:0 Hz
  • Safety and protection - Series operation:No
  • Safety and protection - Parallel operation:Yes
  • Technical data - Signaling and communication - Signaling:
    • 1 x IN1 LED (green)
    • 1 x IN2 LED (green)
    • 1 x OUT LED (green)
  • Technical data - Signaling and communication - Operation status indicator:
    • 2 x Green LED (Ui > 7.5 VDC)
    • 1 x Green LED (Uo > 7.5 VDC)
  • Technical data - Input - Nominal input voltage Ui nom:2 x DC 24 V
  • Technical data - Input - Input voltage range:2 x DC 9 ... 54 V
  • Technical data - Output - Nominal output current Io nom:12.5 A (redundancy operation); 25 A (Parallel operation)
  • Technical data - Output - Nominal output power:600W
  • Technical data - Output - Nominal output voltage Uo nom:DC 24 V
  • Technical data - Output - Output voltage range:DC 9 ... 54 V (Ue - voltage drop)
  • Connection data - Connection type 1:Input/output
  • Connection data - Connection technology:Push-in CAGE CLAMP(R)
  • Connection data - WAGO connector:WAGO 2706 Series
  • Connection data - Solid conductor:0.5 ... 6 mm2 / 20 ... 10 AWG
  • Connection data - Fine-stranded conductor:0.5 ... 6 mm2 / 20 ... 10 AWG
  • Safety and protection - Open-circuit-proof:Yes
  • Safety and protection - Short-circuit-protected:No
  • Safety and protection - Overvoltage protection; secondary:No
  • Technical data - Efficiency/power losses - Efficiency (typ.):0.96
  • Mechanical Data - Mounting type:DIN-35 rail
  • Technical data - Output - Voltage drop:≤ 0.8 V (Input/output)
  • Physical data - Width:50 mm / 1.969 inches
  • Environmental requirements - Ambient temperature (operation):-25 ... +70 °C
  • Environmental requirements - Derating:-2.66°%/K (55°°C < Tu ≤ 70°°C)
  • Environmental requirements - Ambient temperature (storage):-40 ... +85 °C
  • Environmental requirements - Relative humidity: 95% (no condensation permissible)
  • Environmental requirements - Resistance to shock and vibration:Shock: 15g (per EN 60068-2-27)
  • Technical data - Input - Input current Ii:≤ 12.5 A (per path); ≤ 25 A (in total)
  • Commercial data - GTIN:4055140000000
  • Commercial data - ETIM 8.0:EC002540
  • Commercial data - ETIM 7.0:EC002540
  • Commercial data - Customs tariff number:85044083900
  • Technical data - Efficiency/power losses - Power loss Pl:≤ 19 W (nominal load)
  • sku_code:787-783/000-040
  • Environmental Product Compliance - RoHS Compliance Status:Compliant,No Exemption
  • approvals_General approvals:
    • UL - Underwriters Laboratories Inc. - UL 508 - certificate E255817
    • UL - Underwriters Laboratories Inc. - ANSI/ISA 12.12.01 - certificate E484199
  • approvals_Declarations of conformity and manufacturer's declarations:
    • EU-Declaration of Conformity - WAGO GmbH & Co. KG - certificate -
    • UK-Declaration of Conformity - WAGO GmbH & Co. KG - certificate -
  • approvals_Approvals for hazardous areas:
    • ATEX - DEKRA EXAM GmbH - EN 60079-0 - certificate BVS 17 ATEX E 010 X (II 3 G Ex ec IIC T4 Gc)
    • CCC - CNEX - CNCA-C23-01 - certificate 2020312303000474 (Ex ec IIC T4 Gc)
    • IECEx - DEKRA EXAM GmbH - IEC 60079-0 - certificate IECEx_BVS_17.0003X_Issue_02 (Ex ec IIC T4 Gc)
    • UKEx - WAGO GmbH - EN 60079-0 - certificate WAGO22UKEX006X
  • Standards and specifications - Standards/specifications:
    • UL 508
    • ATEX
    • IECEx
    • ANSI/ISA 12.12.01 (Class I Div. 2)
  • Standards and specifications - Conformity marking:CE
  • Safety and protection - Protection class:III
  • Commercial data - Country of origin:CN
  • Safety and protection - Pollution degree:2
  • Safety and protection - MTBF:> 10 million h (per IEC 61709)
  • manufacturer_description:Redundancy Module; 2 x 9 ... 54 VDC input voltage; 2 x 12.5 A input current; 9â€"54 VDC output voltage; 25 A output current
  • picture_filename_1:1024-0200001c00027d7a000100b6-DE.jpg
  • picture_zoom_filename_1:2000-0200001c00027d7a000100b6-DE.jpg
  • Material data - Weight:470g
  • picture_filename_2:1024-0200000b00016dbd000100b6-DE.jpg
  • picture_zoom_filename_2:2000-0200000b00016dbd000100b6-DE.jpg
  • Physical data - Height:130 mm / 5.118 inches
  • manufacturer_detailed_description:

    Features:

    • Redundancy module with two inputs decouples two power supplies.
    • For redundant and fail-safe power supply
    • With LED for input voltage monitoring on site and remotely
  • Physical data - Depth from upper-edge of DIN-rail:92 mm / 3.662 inches
  • Safety and protection - Protection type:IP20; per EN 60529
  • Primary brand: Wago
  • Functions: Redundancy module
  • Supply voltage (DC): 9-54Vdc x 2
  • Rated current: 25A
  • Output voltage (DC): 9-54Vdc (12Vdc / 24Vdc / 48Vdc)
  • Connection type: Push-in CAGE CLAMP spring connections
  • Efficiency: 0.96
  • Mounting mode: DIN-35 rail
  • Dimensions: H130mm x W50mm x D92mm
  • Net Width (mm): 50mm
  • Ambient air temperature for operation: -25°C...+70°C
  • Ambient air temperature for storage: -40°C...+85°C
  • Humidity: 95% relative humidity (RH; non-condensing)
  • GTIN code: 4055140000000
  • ETIM code: EC002540
  • Customs Tariff Number: 85044083900
  • Order code / Manufacturer SKU: 787-783/000-040
  • Manufacturer product status: Commercialized
  • Equivalent to: 787783000000
  • EAN code: 4055140000000
  • Compliant with standard(s):
    • CE
    • ANSI/ISA 12.12.01 (Class I Div. 2)
    • ATEX
    • IECEx
    • UL 508
    • General approvals
    • - UL - Underwriters Laboratories Inc. - UL 508 - certificate E255817
    • - UL - Underwriters Laboratories Inc. - ANSI/ISA 12.12.01 - certificate E484199
    • Declarations of conformity and manufacturer's declarations
    • - EU-Declaration of Conformity - WAGO GmbH & Co. KG
    • - UK-Declaration of Conformity - WAGO GmbH & Co. KG
    • Approvals for hazardous areas
    • - ATEX - DEKRA EXAM GmbH - EN 60079-0 - certificate BVS 17 ATEX E 010 X (II 3 G Ex ec IIC T4 Gc)
    • - CCC - CNEX - CNCA-C23-01 - certificate 2020312303000474 (Ex ec IIC T4 Gc)
    • - IECEx - DEKRA EXAM GmbH - IEC 60079-0 - certificate IECEx_BVS_17.0003X_Issue_02 (Ex ec IIC T4 Gc)
    • - UKEx - WAGO GmbH - EN 60079-0 - certificate WAGO22UKEX006X
    • RoHS compliant
  • Location of origin: China
  • Degree of pollution: 2
  • Level 1 category: Automation components
  • Level 2 category: Power supply units
  • Level 3 category: Redundancy units for power supply circuits
  • Product title: Redundancy module - Wago
More Information
Main function Redundancy unit
Product series / family name 787 series
Supply voltage (DC) 12Vdc, 48Vdc
Rated current 10A < In ≤ 15A
Output voltage (DC) 10Vdc < Vout ≤ 15Vdc, 45Vdc < Vout ≤ 50Vdc
Connection type (electrical) Terminals (Spring)
Mounting mode DIN rail
Degree of protection IP20
Type - Option Standard (No options)
Write Your Own Review